Nanjing Clover Medical Technology Co., Ltd.

Waste Incinerator Made in China

        Call Us on +8625-84610201

Mail: cloverincinerator@Gmail.com

              
   
  
       
   汉语   
  English   
   Pусский  

 Nanjing Clover Medical Technology Co.,Ltd.
 Tel: +86-25-8461 0201
 Fax: +86-25-8461 0406
 Website:
www.clover-incinerator.com
 Email:
cloverincinerator@Gmail.com
 Email:
sales@clover-incinerator.com
 Service Skype ID: clover-incinerator

 Home

 Incinerator Models

 Small Incinerators

 Medical Incinerators

 Pet Crematory

 Contact Us


 Medical Incinerator

Model YD-30 Incinerator

Model YD-50 Incinerator

Model YD-100 Incinerator

Model YD-200 Incinerator

Model YD-150 Incinerator

Model YD-300 Incinerator

Model YD-500 Incinerator

Model YD-600 Incinerator

 Large MSW Incinerator

Model MSW1000 Incinerator

Model MSW2000 Incinerator

Model MSW3000 Incinerator

Model MSW4000 Incinerator

Model MSW5500 Incinerator

 Small Incinerator

Model YD-10 Incinerator New

Model YD-15C Incinerator

Model YD-20C Incinerator

Model YD-30C Incinerator

Model YD-50C Incinerator New

 Pet Crematory

Animal Crematory A360

Animal Crematory A900

Animal Crematory A1500

Animal Crematory A2400

Animal Crematory A4000

Model SYC-50 Incinerator

Model SYC-100 Incinerator

 Economical Incinerator

Model YZ-20 Incinerator

Model YZ-50 Incinerator

Model YZ-100 Incinerator

Model YZ-150 Incinerator

 

 

 

 

 

Small Incinerators

 Clover offer small scale incinerators, standard models are YD-15C, YD-20C, YD-30C and also can offer smaller model, model YD-5C and YD-10C for market.

     

 

Equipment Technical Specifications

Model

YD-15C

YD-20C YD-30C

Feed Capacity

40-80 kgs per feed

40-80 kgs per feed

50-100 kgs per feed

Burning Rate

15 kgs per hour

20 Kgs per hour 30 Kgs per hour

Voltage

220V

Power

0.50Kw

0.50Kw 0.59Kw

Fuel

Natural Gas or Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

4.4-9.4 Kgs/Hour

5.4-12.6 Kgs/Hour 10.2-20.0 Kgs/Hour

Fuel consumption (Gas)

5.3-11.2 m3/Hour

6.5-15.0 m3/Hour 12.2-20.0 m3/Hour

Waste combustion chamber

200Liters

200Liters

250Liters

Post Combustion Chamber

140Liters

140Liters

140Liters

Door Opening

38 x 48cm

Chimney

5.0M

Gross Weight

1200kgs

1200kgs 1800kgs

Chamber Material

Refractory Concrete

Max. Heat Value

94,000Kcal/Hr.

126,000Kcal/Hr. 200,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

800 0C -1000 0C

Gas Chamber temperature

1000 0C -1200 0C

Chamber Anti-Rate

13500C

Residency time

2.0 Sec.

Burning efficiency

98%

 

 

 

 

 

 

  