Author: hiclover

  • Technical specification for burning machine

    Technical specification for burning machine

    Technical specification for burning machine
    1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to 
    burn different kinds of drugs. All need equipment must be provided.
    2.Warrantee:  booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative 
    maintenance repair and corrective maintenance must be included in the cost and provided to the customer.
    3.All needed electric and water connections must be provided.
    4.Both systems must be of high quality and must be environmental friendly.
    5.The capacity of each system should be up to 100 kg/hr.
    6.The system must have automatic feeding.
    7.Each system must consists of two burning  rooms, one primary room for burning the drug and another room for burning the gases  that emit as 
    a result of primary burning. 
    8.The oven must be made of steel that is rust resistance and with thickness not less than 6 mm.
    9.Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for burning organic materials.
    10.Waste products should not exceed 5%.
    11.System must have automatic ignition system. 
    12.System should use diesel (HSD) as fuel and should not consume more than  8 to 10 lt/hr . 
    13.Each system should be provided with fuel tank  of size adequate to operate the system for one full day.
    14.The temperature in the primary room should be 850 C ± 50 C. the system should also be capable to operate up to 1050 C ± 50 C. the system 
    should be capable of continues operation and should be provided with cement layer insulator with adequate thickness.
    15.Oven should be provided with heat insulator to allow easy operation.
    16.Gas should remain in the secondary room for not more than 1.5 second. 
  • Incinerator Technical Specifications

    Incinerator Technical Specifications

    Incinerator Technical Specifications
    Parameter Description Property
    CHIMNEY – Standard top type – Self supporting
    PERFORMANCE Temperature Not less than 11000C
    Capacity (kg/hr.) 10
    Waste type  paper, clothing, packaging, rags, pallets, polythene and others
    Air pollution Standard The Environment Conservation Rules, 1997
    DIMENSIONS Height(mm) 2256
    Length (mm) 725
    Width (mm) 725
    Door opening 490×390 mm
    Chamber volume(m3) 0.5
    Stack diameter(mm) 200
    Grate/Hearth area(m2) 0.4
    MATERIALS Casing 3.0mm & 4.5mm mild steel
    Loading Door High grade cast iron
    Grate/Hearth support Heavy mild steel plate lined with cast able refractory and insulation
    Ashing door High grade cast iron
    Insulation wall High temperature insulation bricks
    Refractory High alumina monolithic
    Air supply Natural
    Firing system
    Free burning or diesel/Oil/NG for non-combustible product
    Painting Casting Hammerite deep green
    Roof Hammerite silver grey
    Stack-mild Steel Hammerite silver grey
    Foundation Flat and level  Concrete Base under the incinerator
    Insulation walls High Temperature insulation bricks
  • Spesifikasi Incinerator 200kg/jam

    Spesifikasi Incinerator 200kg/jam

    Spesifikasi Incinerator 200kg/jam
    Spesifikasi dan Daftar Material
    Dimensi dan Power Capacity
    Nama Barang                                : INCINERATOR
    Type / Model                 : PWR-INC-KMN 20
    Kapasitas                                 : 200kg/Jam (2 m3)
    Length                               : 384 cm  
    Width                                : 182 cm  
    Height                                    : 213 cm  
    Height of Chimney std            : 700 cm  
    TOTAL WEIGHT                   : 9.500 kg 
    Panel – timer                 : Digital Included Auto Alarm
    Finishing                            : Hot endured paint 
    Fuel tank                           : 200 Liter 
    Covering Element from steel   : 3-8mm 
    Banyaknya Burner                   : 3 pcs  
    Banyaknya Blower               : 2 pcs 
    Max. Fuel consumption           : 15-40 Liter/Jam 
    Max. Elektric consumption   : 1300 Watt  
    Bahan bakar               : Kerosene / Diesel (solar)  
    Voltage                              : 220 V / 1 phase / 50 Hz  
    Material 
    1. PANEL CONTROL
    Type                       : Digital 
    Buatan                    : Local KAMINE ( Panel dan Incinerator satu Merek)
    Voltage                   : 220 V / 1 phase / 50 Hz  
    Safety operator       : Emergency Stop 
    System                    : Microkontroller 
    Pengoperasian         : Semi Automatic
    Temperatur control  : Digital Coupler Type
    Control panel : Manual dan automatic
    Tipe : Self Standing Type / Wall Mounted Type
    Material  : Mild steel
    Thermocontrol : 2 (Dua)  1200 ºC
    Set of timer : 0- 2 jam
    Tombol saklar : on/off
    2. CONTRUCTIONS
        
    Fire Brick                  : SK 34
    Castable                          : R 16
    Castable                    : R 14
    Isolator                   : Insulating Brick serat tahan panas Keramik 1.450 ⁰ C
    Element from steel     : 3-8 mm
    Finishing                     : Cat Fetalit coating, Epoxy Resin (hot-endured paint)
    Total berat keseluruhan     : 9.500 kg
    Ketebalan Dinding Dalam : 21 Cm
    3.DIMENSION OF CHAMBER (Dimensi Ruang Bakar)
    Chamber 1 Ruang Bakar Utama : 130 x 115 x 132 cm = 1.973.400 cm3 = 1.97 m3
    Chamber 2  Ruang Bakar Kedua: 50 x 115 x 132 cm = 759.000 cm3= 0.76 m3
    4. EXHAUST STACK (Chimney)
             –     Diameter (inch): Ø 12″, 10″
    -Panjang: 700 cm (7 m) dari permukaan tanah 
    -Cerobong pertama dengan system Cor tipe MWHT
    -Material Mild steel ( Baja Hitam )
    5. INSTRUMENTATION & KONTROL
                          1. Suhu Control: Optimal
                               – Model: Digital
                               – Jumlah (unit): 2 (dua) unit
                               – Kontrol Mode: On-Off
                          2. Power Supply (volt / fase / herts): 15A / 220 V / 1 Phase / 50 Hz
                          3. Panel kandang: Mild Steel + powder coating
                          4. Thermocouple: K
                               – Jumlah: 2 (dua) unit
                               – Bahan: Stainless Steel + Ceramic
                          5. Timer: 0-2 Jam
                          6. De-ashing: Manual
              7. System pembuangan Abu 2 unit 
    6. PINTU 
    Pintu    : Baja ringan dan Linning dengan castable 
    System : Double lock system ( penguncian ganda )
    7. AIR SUPPLY SYSTEM 
    Model / Type: fan sentrifugal 3 “
    Kapasitas (m3/minute): 3.000 m3/mnt
    Statis Tekanan (mmAq): 98 mmAq
    Power : 200 watt/unit
    Jumlah (unit): 2 (dua)
    8. FUEL SYSTEM
     Pembakaran Burner:
    Type: Gun type OM 2N
    Bahan Bakar: Diesel Oil / Kerosene
    Konsumsi Bahan Bakar: 10-18 ltr / jam
    Power : 250 watt
    Jumlah unit : 1 unit 
    Type: Gun type OM 2N
    Bahan Bakar: Diesel Oil / Kerosene
    Konsumsi Bahan Bakar: 10-18 ltr / jam
    Power : 250 watt
    Jumlah unit : 1 unit 
    Type: Gun type OM 2N
    Bahan Bakar: Diesel Oil / Kerosene
    Konsumsi Bahan Bakar: 10-18 ltr / jam
    Power : 250 watt
    Jumlah unit : 1 unit 
    9. THERMOCOPLE
    Ruang bakar pertama dan kedua
    Tipe : K
    Protective tube : Stainless steel + ceramic
    Max. temperature : 1200 ºC
    Jumlah : 2 unit
    Sistem pemberian umpan : Manual
    Sistem pengeluaran hasil : Manual
    10. TANGKI BAHAN BAKAR
    Material : Mild steel
           Kapasitas : 200 liter
  • Incinerator walls and roof

    Incinerator walls and roof

    21.Refractory material :alumina content> 49% and thickness average 102mm
    22.Bake out : to be done over 2-3 days
    23.Materials of constructions
    Case :5mm mild steel
    Bracing: heavy angle and channel
    Hearth: 1550 ⁰C
    Ashing door: high grade cast iron
    Loading door 5mm mild steel lined with 1550 ⁰C castable general purpose high strength, high abrasion resistant monolithic refractory 
    concrete.
    Incinerator walls and roof: 1550 ⁰C castable monolithic refractory
    24.Temperature: ≥ 90 ⁰C
    25.Insulation to walls: 1000 ⁰C castable insulation
    26.Electricity supply required: 220volt, 15amp single phase
    27.Controls:
    Draught control: barometer indicator, door operated draught limiter
    Air supply: built-in forced heated air ducts, primary and secondary (intensifier)
    Electric: control panel includes-circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer
    Summary of Key Expected Activities/Outputs
    Replacement of pipes from the tank to the incinerator
    Covering pipes to protect them bursting in winter
    Replacement of gauge
    Incinerator installation
    Installation report
    End of contract report
  • Evaluation of Vendor offer for Solid Sludge Waste Incinerator

    Evaluation of Vendor offer for Solid Sludge Waste Incinerator

    Square Textiles Division
    Evaluation of Vendor offer for Solid Sludge Waste Incinerator 
    Criteria Our Requirement Vendor
    Brand/Manufacturer Nanjing Clover
    Local Agent N/A
    Country of Origin China
    Offer Reference 2016072701N211
    Technical Details
    Model of Incenarator WS-100
    Capacity 100 Kg/Hr
    Type of Waste Used “1. Sludge of ETP
    2. Waste Fabric and Yarn
    3. Kitchen Waste (includes dry objects and polythene bags)
    4. Paper/Carton
    5. Spinning Mill AC dust/ Micro Dust”
    Line Diagram PCC-SCC-Chimney-Water Tank-Spray Scrubber-Fog & Water Separator-ID System-Chimney
    No of Combustion Chamber 2 2
    Temperature Range at PCC 800 C 800°C-1000°C
    Temperature Range at SCC 1000 C 1000°C-1200°C
    Useful Life of Incinerator 10 Years
    Operating Hour/Day Continuous (24 Hours) 16
    Total Power Consumption (KW)
    Space Requirement for the plant (L x W x H)
    Primary Combusion Chamber
    Chambers Construction Material  Steel
    Type of Refractory Material
    Refractory Lining Thickness
    Conductivity of Refrectory Materials
    Constituents of Refrectory Materials
    Volume of Primary Comustion Chamber 1500 Ltr
    Type of Insulation Material
    InsulationThickness
    Conductivity of Insulation Materials
    Opening Door Size
    Material Handling and Feeding type Semi-Automatic
    Secondary Combusion Chamber
    Chambers Construction Material  Steel
    Type of Refractory Material
    Refractory Lining Thickness
    Conductivity of Refrectory Materials
    Constituents of Refrectory Materials
    Volume of Secondary Comustion Chamber 500 Ltr
    Type of Insulation Material
    InsulationThickness
    Conductivity of Insulation Materials
    Burner
    No of Burner
    Burner Model
    Burner Brand & Origin
    Motor’s Brand & Origin
    Power Consumption of Burner Motor
    Motor Efficiency Class/Insullation Class/Protection Class
    Fuel Type Natural Gas & Diesel
    Natural Gas Consumption 20-44 Kg/Hr
    Diesel Consumption 12-41.2 M³/Hr
    Oil Tank Capacity 300 Ltr
    FD Fans
    Number Of FD Fan
    Type of FD Fan
    Motor Brand & Origin for FD Fans
    Motor Efficiency Class/Insullation Class/Protection Class
    Construction material of Fan Body
    Construction material of Fan Impeller
    Power Consumption of Fan Motor
    “Electrical Supply 
    (Voltage, Current, Phase, Frequency)”
    Fan Flowrate (m3/min)
    Pressure Head (m)
    ID Fans
    Number Of ID Fan
    Type of ID Fan
    Motor Brand & Origin for ID Fans
    Motor Efficiency Class/Insullation Class/Protection Class
    Construction material of Fan Body
    Construction material of Fan Impeller
    Power Consumption of Fan Motor
    “Electrical Supply 
    (Voltage, Current, Phase, Frequency)”
    Fan Flowrate (m3/min)
    Pressure Head (m)
    High Temperature Chimney
    Duct Diameter
    “Duct Material of Construction  
    (mention grade)” Steel
    Thickness of Duct
    Type of Insulation Used
    Insulation Thickness
    Inside Lining for Duct
    Water Tank
    Water Tank Capacity
    Matial Construction (mention grade) Steel
    Wet Cooling Spray Scrubber
    Nozzle Material Construction (mention grade) Steel
    Dosing System
    Dosing Pump Model
    Dosing Pump Brand & Origin
    Dosing Pump Capacity
    Scrubbing Medium
    Material of Construction of Venturi Scrubber
    Material of Construction of Bed Scrubber
    Waste Water Sink
    Tank Construction Material (mention grade)
    Tank Dimension (L x W x H)
    PH Control System  Must be added
    Dosing System
    Dosing Pump Model
    Dosing Pump Brand & Origin
    Dosing Pump Capacity
    Pump & Recirculation System
    Number of Pumps
    Pump Brand & Origin
    Pump Flowrate (m3/min)
    Pressure Head (m)
    Power Consumption (KW)
    Motor Efficiency Class/Insullation Class/Protection Class
    Construction Material of Pump Body
    Construction Material of Pump Impeller
    Wet Dust Filter
    Material of Construction (mention grade)
    Cleaning System
    Filtration System Type
    Frequency of Replacement/ Maintenance
    Seive Size
    Mesh size of filter
    Fog and Water Separator
    Material of Construction (mention grade)
    Chimney & Others
    Main Stack/Chimney Height
    Material of Construction of Chimney
    Inside Lining of Chimney Duct
    Control System (Alarms, Displays, Trips, Automatic Shutdown)
    Alarms (please list down the alarm conditions) “1.
    2.
    ,etc..”
    Displays (please list down the displays) “1.
    2.
    ,etc..”
    Failure Conditions (please list down the failure conditions) “1.
    2.
    ,etc..”
    Trip Conditions (please list down the conditions the system will trip) “1.
    2.
    ,etc..”
    Shutdown conditions (Please list down the conditions under which the system will shutdown) “1.
    2.
    ,etc..”
    Reference Factory
    Commercial Details
    Delivery Time
    Payment Method LC at Sight
    Price Basis C& F, Chittagong
    Warranty 2 Years from Comissioning
    Ex-Work Price
    Freight Cost
    Installation & Commisioning
    Total Offered Price
  • HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR

    HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR

    HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR
    1.Capacity of destruction in weight: 60Kg/h
    2.It should be able to operate not less than 10 hours/day.
    3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, 
    laboratories, institutes, etc..
    4.Design Specification: Types A, B, C, D and E of medical waste
    5.“PYROLYTIC” combustion by controlling the gasification of waste.
    6.The incinerator must avoid the release of black smoke and fine dust, (smokeless) during the loadings.
    7.It should be able to reduce the volume of wastes by 98%
    8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.
    9.The incineration should be completely free from visible smoke as well as offensive odours.
    10.  The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
      the temperatures of combustion: Minimum will be 850oC and max 1400oC
      post combustion:>1100oC
    11.  The internal diameter of the chimney:Ø400 and its height: 8m
    12.  The volume of the combustion chamber: 1,200L
    13.  The dimension of the door for loading in cm: 70 x 70
    14.  Burner operation should be automatic on/off

  • Containerized mobile incinerator CA50

    Containerized mobile incinerator CA50

    The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.

    HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

    Model CA50
    Waste Treatment Waste Incineration Treatment
    Feed Capacity Average 100 kgs per feed
    Burning Rate Average 50 kgs per hour
    Burning Time per Feed Average 2 hour
    Control Mode PLC(Programmable Logic Controller Incinerator)
    Voltage 220V
    Power 0.7Kw
    Fuel Diesel oil
    Burner Italy Burner
    Feed Mode Manual
    Temperature Monitor Digital Display
    Fuel consumption (Oil) Average 16.6 Kgs/Hour
    Internal Dimensions 100x80x70cm (Primary Chamber)
    External Dimensions 230 x 130 x 155cm (main body)
    Waste combustion chamber 560Liters
    Post Combustion Chamber 280Liters
    Oil Tank Capacity 200 Liters
    Door Opening 70 x 50cm
    Chimney 5.0M
    Gross Weight 4500kgs
    Chamber Material Firebrick ,Refractory Concrete
    Max. Heat Value 166,000Kcal/Hr.
    Operation Technical Specifications
    Solid Chamber temperature 8000C -10000C
    Gas Chamber temperature 10000C -12000C
    Chamber Anti-Rate 14500C
    Residency time 2.0 Sec.
    Burning efficiency >98%
    Waste Lower Calorific Power 3000Kcal
  • Small Medical Incinerator TS100

    Small Medical Incinerator TS100

    We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.

    Items/Model TS100(PLC)
    Burn Rate (Average) 100 kg/hour
    Feed Capacity(Average) 200 kg
    Control Mode PLC
    Combustion Chamber 1200L
    Internal Dimensions 120x100x100cm
    Secondary Chamber 600L
    Smoke Filter Chamber Yes
    Feed Mode Manual
    Voltage 220V
    Power 0.7Kw
    Oil Consumption (kg/hour) 14–28
    Gas Consumption (m3/hour) 10–32.2
    Temperature Monitor Yes
    Temperature Protection Yes
    Oil Tank 200L
    Feed Door 80x60cm
    Chimney 10Meter
    Chimney Type Stainless Steel
    1st. Chamber Temperature 800℃–1000℃
    2nd. Chamber Temperature 1000℃-1200℃
    Residency Time 2.0 Sec.
    Gross Weight 6000kg
    External Dimensions 260x150x180cm
  • Small Medical Incinerator TS50

    Small Medical Incinerator TS50

    HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

    Items/Model TS50(PLC)
    Burn Rate (Average) 50 kg/hour
    Feed Capacity(Average) 100kg
    Control Mode PLC
    Combustion Chamber 560L
    Internal Dimensions 100x80x70cm
    Secondary Chamber 280L
    Smoke Filter Chamber Yes
    Feed Mode Manual
    Voltage 220V
    Power 0.7Kw
    Oil Consumption (kg/hour) 12.1–24
    Gas Consumption (m3/hour) 9.9–26.1
    Temperature Monitor Yes
    Temperature Protection Yes
    Oil Tank 100L
    Feed Door 70x55cm
    Chimney 5Meter
    Chimney Type Stainless Steel
    1st. Chamber Temperature 800℃–1000℃
    2nd. Chamber Temperature 1000℃-1200℃
    Residency Time 2.0 Sec.
    Gross Weight 4500kg
    External Dimensions 230x130x155cm
  • Small Medical Incinerator TS30

    Small Medical Incinerator TS30

    Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

    The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

    Items/Model TS30(PLC)
    Burn Rate (Average) 30 kg/hour
    Feed Capacity(Average) 60kg
    Control Mode PLC
    Combustion Chamber 330L
    Internal Dimensions 75x75x60cm
    Secondary Chamber 180L
    Smoke Filter Chamber Yes
    Feed Mode Manual
    Voltage 220V
    Power 0.5Kw
    Oil Consumption (kg/hour) 10.2–20
    Gas Consumption (m3/hour) 9.8–20
    Temperature Monitor Yes
    Temperature Protection Yes
    Oil Tank 100L
    Feed Door 55x50cm
    Chimney 5Meter
    Chimney Type Stainless Steel
    1st. Chamber Temperature 800℃–1000℃
    2nd. Chamber Temperature 1000℃-1200℃
    Residency Time 2.0 Sec.
    Gross Weight 3000kg
    External Dimensions 175x120x140cm